Influence of the position of the MHD stirrer relative to the crucible on the driven liquid metal flow

S. Yu. Khripchenko1 , R. R. Siraev2 , S. A. Denisov1 , V. M. Dolgikh1 , I. V. Kolesnichenko1

1 Institute of Continuous Media Mechanics UB RAS, 1 Korolev str., 614013 Perm , Russia
2 Perm National Research Polytechnic University, 29 Komsomolsky pr., 614990 Perm, Russia

Abstract
In this paper, the influence of the position of the MHD stirrer relative to the crucible on the driven liquid metal flow has been studied both experimentally and numerically. Analysis of the obtained results has revealed that the intensity of the liquid metal flow in the crucible slightly decreases when its bottom is removed from the lower edge of the MHD stirrer inductor. Figs 7, Refs 13.

Magnetohydrodynamics 54, No. 4, 383-390, 2018 [PDF, 1.01 Mb]

Copyright: Institute of Physics, University of Latvia
Electronic edition ISSN 1574-0579
Printed edition ISSN 0024-998X
DOI: http://doi.org/10.22364/mhd